1. Scope
This technical specification defines the performance requirements, mechanical characteristics, environmental adaptability, test methods, and compliance criteria for the Ultra-Low Loss 1x4/1x8 Direct-Input Molded LGX PLC Splitter (hereinafter referred to as "the splitter"). Designed for high-reliability optical communication networks, the splitter complies with relevant standards of the International Electrotechnical Commission (IEC) and Telecordia, ensuring compatibility and stable operation in global optical network deployments.
2. Normative References
The following standards are essential for the application of this specification. For dated references, only the edition with the specified date applies; for undated references, the latest edition (including all amendments and corrigenda) shall be followed.
• IEC 61753-1: Fibre optic interconnecting devices and passive components – Performance specifications – Part 1: General and guidance
• IEC 61753-021: Fibre optic interconnecting devices and passive components – Performance specifications – Part 021: Single-mode fibre components (category U)
• IEC 60793-1: Optical fibres – Part 1: Generic specification
• IEC 60793-2-50: Optical fibres – Part 2-50: Product specification – Class B single-mode fibres (G.652.D)
• Telecordia GR-1209-CORE: Generic Requirements for Passive Optical Components
• Telecordia GR-1221-CORE: Generic Requirements for Fibre Optic Connectors and Jumpers
• Telecordia GR-449-CORE: Generic Requirements for Fibre Optic Cables
Specification
3. Product Overview
3.1 Basic Configuration
Item | Specification (1x4 Model: PLC-LGX-1x4-DI-UL) | Specification (1x8 Model: PLC-LGX-1x8-DI-UL) |
Splitting Ratio | 1 input port → 4 output ports (uniform distribution) | 1 input port → 8 output ports (uniform distribution) |
Input/Output Design | Direct input structure, no additional adapter; compatible with LGX package footprint | Direct input structure, no additional adapter; compatible with LGX package footprint |
Fibre Type | Single-mode fibre (SMF), compliant with IEC 60793-2-50 G.652.D | Single-mode fibre (SMF), compliant with IEC 60793-2-50 G.652.D |
Fibre Length | Customizable (standard: 1.0 m; optional: 0.5 m / 1.5 m / 2.0 m) | Customizable (standard: 1.0 m; optional: 0.5 m / 1.5 m / 2.0 m) |
Package Type | Molded exclusive LGX package (metal-reinforced plastic), compatible with standard 19-inch optical distribution frames (ODFs) | Molded exclusive LGX package (metal-reinforced plastic), compatible with standard 19-inch optical distribution frames (ODFs) |
Connector Type (Optional) | SC/PC, LC/PC, FC/PC (compliant with IEC 61754-4, IEC 61754-20) | SC/PC, LC/PC, FC/PC (compliant with IEC 61754-4, IEC 61754-20) |
3.2 Working Principle
The splitter adopts advanced Planar Lightwave Circuit (PLC) technology, where a single-mode optical signal is coupled into a planar waveguide chip. The waveguide structure is precisely etched to distribute the optical power uniformly to multiple output waveguides, ensuring low insertion loss, high splitting uniformity, and stable performance across the operating wavelength range.
4. Performance Requirements
4.1 Optical Performance
All optical parameters shall be measured at 23 °C ± 2 °C, 50% ± 10% relative humidity, unless otherwise specified.
Parameter | Requirement (1x4 Model) | Requirement (1x8 Model) | Test Standard |
Insertion Loss (IL) | ≤ 7.2 dB (at 1310 nm); ≤ 7.3 dB (at 1550 nm); ≤ 7.5 dB (at 1625 nm) | ≤ 10.5 dB (at 1310 nm); ≤ 10.6 dB (at 1550 nm); ≤ 10.8 dB (at 1625 nm) | IEC 61753-021, Telecordia GR-1209-CORE Method 4.2 |
Polarization Dependent Loss (PDL) | ≤ 0.15 dB (maximum, over 1260 nm - 1650 nm) | ≤ 0.15 dB (maximum, over 1260 nm - 1650 nm) | IEC 61753-021 Method 4.3 |
Return Loss (RL) | Input port: ≥ 55 dB; Output ports: ≥ 50 dB (at 1310 nm/1550 nm/1625 nm) | Input port: ≥ 55 dB; Output ports: ≥ 50 dB (at 1310 nm/1550 nm/1625 nm) | Telecordia GR-1209-CORE Method 4.4 |
Splitting Uniformity | ≤ 0.4 dB (maximum deviation between any two output ports) | ≤ 0.4 dB (maximum deviation between any two output ports) | IEC 61753-021 Method 4.5 |
Operating Wavelength Range | 1260 nm - 1650 nm (full C-band, L-band, and extended L-band coverage) | 1260 nm - 1650 nm (full C-band, L-band, and extended L-band coverage) | IEC 61753-1 Clause 5 |
Chromatic Dispersion | ≤ ±3 ps/nm/km (at 1550 nm) | ≤ ±3 ps/nm/km (at 1550 nm) | IEC 60793-1 Method 6.2 |
4.2 Mechanical Performance
Parameter | Requirement | Test Standard |
Connector Retention Force | Axial direction: ≥ 220 N; No connector damage or fibre displacement after 10 cycles of insertion/extraction | Telecordia GR-1221-CORE Method 5.1 |
Package Mechanical Strength | Withstand static load of 120 N applied vertically to the package surface for 1 minute; No deformation, cracks, or optical performance degradation (ΔIL ≤ 0.1 dB) | IEC 61753-1 Method 7.2 |
Fibre Bending Resistance | Static bending radius: ≥ 30 mm (no ΔIL > 0.1 dB); Dynamic bending radius: ≥ 50 mm (1000 cycles, ΔIL ≤ 0.1 dB) | Telecordia GR-449-CORE Method 6.3 |
Vibration Resistance | Frequency range: 10 Hz - 500 Hz; Amplitude: 0.38 mm (peak-to-peak); Duration: 2 hours (X/Y/Z axes); ΔIL ≤ 0.1 dB | IEC 61753-1 Method 7.3 |
Shock Resistance | Half-sine wave; Peak acceleration: 100 g; Pulse duration: 6 ms (X/Y/Z axes); No structural damage, ΔIL ≤ 0.1 dB | Telecordia GR-1209-CORE Method 5.3 |
5. Environmental Requirements
5.1 Operating Temperature Range
• Standard Operation: -40 °C to +85 °C (ΔIL ≤ 0.3 dB throughout the range)
• Extended Operation (Optional): -55 °C to +95 °C (ΔIL ≤ 0.5 dB throughout the range)
5.2 Storage Temperature Range
• -55 °C to +95 °C; No performance degradation after 1000 hours of storage at extreme temperatures
5.3 Humidity Resistance
• Operating Humidity: 5% - 95% RH (non-condensing, 23 °C ± 2 °C); ΔIL ≤ 0.1 dB
• Damp Heat Test: 40 °C, 93% RH (non-condensing) for 1000 hours; No corrosion, ΔIL ≤ 0.2 dB (per IEC 61753-1 Method 8.2)
5.4 Salt Spray Resistance
• 5% NaCl solution; Temperature: 35 °C; Duration: 96 hours; No visible corrosion on metal parts, ΔIL ≤ 0.2 dB (per Telecordia GR-1209-CORE Method 5.6)
6. Test Methods
All tests shall be conducted by qualified laboratories with calibrated equipment, following the procedures specified in the normative references. Key test methods include:
• Optical Performance Test: Use an optical power meter and light source (compliant with IEC 61753-021) to measure IL, PDL, RL, and splitting uniformity.
• Mechanical Test: Apply static load, vibration, and shock using specialized test equipment; Verify connector retention force with a tensile tester.
• Environmental Test: Use environmental chambers to simulate extreme temperature, humidity, and salt spray conditions; Monitor optical performance before/after tests.
7. Compliance & Quality Assurance
• The splitter shall fully comply with the requirements of IEC 61753-021 (category U, grade 1) and Telecordia GR-1209-CORE (level 1).
• Each unit shall undergo 100% factory inspection (optical, mechanical, and visual checks) before shipment.
• Quality Assurance Period: 5 years from the date of delivery (under normal operating conditions, free repair/replacement for non-human-induced failures).
8. Marking & Packaging
8.1 Product Marking
Each splitter shall be marked with the following information (permanent, wear-resistant):
• Product Name: Ultra-Low Loss 1x4/1x8 Direct-Input Molded LGX PLC Splitter
• Part Number: PLC-LGX-1x4-DI-UL / PLC-LGX-1x8-DI-UL
• Splitting Ratio, Fibre Type (G.652.D), Fibre Length
• Compliance Marks: "IEC 61753-021" / "Telecordia GR-1209-CORE"
• Manufacturing Date (YYYY-MM) and Serial Number
8.2 Packaging
• Individual Packaging: Anti-static plastic bag + foam buffer (moisture-proof, shockproof)
• Carton Packaging: Corrugated carton with desiccant; Maximum 20 units per carton
• Packaging Label: Includes part number, quantity, weight, and handling instructions ("Handle with Care", "Keep Dry")
Product Advantage
-
1
Ultra-Low Optical Loss & Superior Signal Uniformity
Industry-Leading Insertion Loss: 1x4 (≤7.2 dB @1310nm) / 1x8 (≤10.5 dB @1310nm) — 0.3-0.5 dB lower than mainstream competitors, reducing signal attenuation and extending transmission distance by up to 15% in FTTH/5G backhaul networks.
Minimal PDL (≤0.15 dB): Ensures stable signal transmission across all polarization states, avoiding performance fluctuations in high-speed optical systems.
Tight Uniformity (≤0.4 dB): Uniform power distribution among output ports eliminates "weak signal" issues in multi-user scenarios, improving network reliability. -
2
Direct-Input Molded LGX Design: Cost & Space Efficiency
Adapter-Free Direct Input: Integrates input port directly with the PLC chip, removing redundant adapters to reduce insertion loss (0.2 dB saved) and component cost. Compatible with standard LGX packages, enabling plug-and-play integration into 19-inch ODFs without additional modifications.
Molded Reinforced Package: Metal-reinforced plastic housing (exclusive mold) offers 30% higher mechanical strength than conventional plastic packages, while reducing weight by 20% — ideal for space-constrained data centers and outdoor cabinets. -
3
Extreme Environmental Adaptability & Durability
Wide Temperature Range (-40°C to +85°C): Complies with harsh operating conditions in polar regions, deserts, and high-altitude areas (exceeds Telecordia GR-1209-CORE’s standard range of -20°C to +70°C).
Rugged Mechanical Performance: Withstands 120N static load, 100g shock, and 1000 cycles of dynamic bending (radius ≥50mm) — no optical performance degradation (ΔIL ≤0.1 dB), ensuring 24/7 stability in industrial or outdoor deployments.
5-Year Warranty: Backed by strict 100% factory inspection (optical/mechanical/visual) and long-term reliability testing (1000h damp heat, 96h salt spray), reducing B2B customers’ maintenance costs and downtime risks. -
4
Global Standard Compliance & Universal Compatibility
Dual-Certified (IEC 61753-021 Category U / Telecordia GR-1209-CORE Level 1): Meets international technical norms, ensuring seamless compatibility with global optical network infrastructure (e.g., European FTTH, Middle Eastern 5G projects, Latin American data centers).
G.652.D Fibre & Multi-Connector Support: Compatible with standard single-mode fibres and optional SC/LC/FC connectors (IEC 61754), adapting to diverse customer network architectures without customization delays. -
5
Cost-Optimized Total Ownership (TCO) for B2B Partners
Reduced Installation Time: Direct-input design and LGX standard footprint cut on-site integration time by 40% compared to non-standard splitters.
Low Maintenance: High-quality PLC chip (from top-tier suppliers) and precision molding process reduce failure rate to <0.05% annually, lowering long-term replacement and labor costs for telecom operators, system integrators, and data center owners.
Customizable Fibre Length: 0.5m-2.0m flexible options eliminate waste from excess cable, optimizing material costs for specific project requirements. -
6
Exclusive Mold Design & Brand Differentiation
NOARK-exclusive molded LGX package ensures structural uniqueness, avoiding patent disputes and enhancing product competitiveness for B2B customers in bidding scenarios.
Compact, lightweight design (20% lighter than metal packages) reduces shipping costs by up to 15% for bulk orders — a key advantage for global distributors and project-based clients.
Each advantage is validated by third-party laboratory tests (per IEC 61753-021 & Telecordia GR-1209-CORE) and field-proven in 500+ global projects (FTTH, 5G, data centers), delivering tangible value for NOARK’s B2B partners in terms of performance, cost, and market competitiveness.