DC MCB (≤1000Vdc)
DC MCB (≤1000Vdc)

DC MCB (≤1000Vdc)

Basic Info: 1000V DC miniature circuit breaker, compliant with IEC/EN 60947-2, mainly for PV systems.

Main Function: Provides overload, short-circuit protection and circuit isolation.

Key Parameters: 6kA breaking capacity, max 63A, K-type trip curve, non-polarized DC wiring.

Structure: Compact 2/4-module design, DIN rail mount, supports various accessories.

Application: Suitable for PV, energy storage and other low-voltage DC systems.

Benefit: Polarity-free installation, simple assembly and strong scalability.

Share:

  • Product Description
  • Specification
  • Product Advantage

Product Description

1. Product Overview

This DC miniature circuit breaker is engineered for photovoltaic DC power distribution systems, delivering overload, short-circuit protection and circuit isolation function. It adopts non-polarized design to simplify PV system wiring layout, fully tested and compliant with global low-voltage switchgear standards.

2. Applicable Standard

IEC / EN 60947-2

Specification

3. Core Electrical Technical Parameters

Parameter Item

Technical Value

Total Rated Operating Voltage (Ue)

1000 V DC

Rated Operating Voltage per Single Pole

250 V DC

Rated Short-Circuit Breaking Capacity (Icu)

6 kA

Tripping Characteristic Curve

K curve thermal-magnetic trip

Rated Current Range (In)

Up to 63 A

Pole Module Width Specification

2 modules, 4 modules

Polarity Design

Non-polarized, bidirectional DC wiring allowed

4. Mechanical & Installation Features

1. Standard DIN rail mounting structure, modular compact design

2. Wide range of matching electrical accessories for customized system configuration

3. Clear on/off status indicator for visual circuit isolation confirmation

4. Optimized arc extinguishing structure specially adapted for DC fault current breaking

5. Application Scope

Photovoltaic solar power generation DC combiner boxes, PV string circuits

Energy storage DC distribution loops

Other low-voltage DC power systems requiring overload & short-circuit protection

6. Available Supporting Documents

1. Product Catalogue (PDF)

2. Global Safety Certification Document (PDF)

3. Installation & Operation Manual (PDF)

7. Key Performance Advantages

Non-polarized wiring eliminates positive/negative pole installation restrictions for PV arrays

High DC breaking capacity reliably cuts short-circuit fault current in photovoltaic DC loops

K-type trip curve matches the overload characteristic of solar PV modules

Modular width options flexible for different cabinet layout space requirements

Complete accessory portfolio supports auxiliary contact, shunt trip, undervoltage trip and other expansion functions

Product Advantage

  • 1

    Polarity-free wiring: Bidirectional DC wiring without positive/negative pole restrictions.

  • 2

    Stable fault protection: 6kA breaking capacity for DC overload and short-circuit faults.

  • 3

    PV adaptive trip: K-type curve fits photovoltaic system operating characteristics.

  • 4

    Flexible layout: 2/4 module optional sizes for various cabinet installation.

  • 5

    Good expandability: Compatible with multiple auxiliary functional accessories.

  • 6

    Broad applicability: Works for PV, energy storage and low-voltage DC systems.

BackUp

Contact Us

Inquire